DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 65
Bosch Security Systems | 8/04 | 4998153891C
PIN, User #
Address: See Table 10 on page 64
Default:
User 1: 1, 2, 3, 4, 5, 6, 7
Users 2-32: 15, 15, 15, 15, 15, 15, 15
Selections: 0 to 9
Enter a PIN for each user in the PIN parameter. The PIN length parameter determines the number of digits in the
PINs.
The default PIN length is 4 digits, which makes all User PINs four digits in length. For example, if a User PIN is
7654321 and the PIN length is set to 4 digits, the User PIN changes to 7654.
Do not use digits 10 to 15 when creating a User PIN. Entering these digits makes the PIN unusable
and locks the user out of the control panel.
Authority Level, User #
Address: See Table 10 on page 64
Default:
User 1: 1 (Authority Level 1)
Users 2-32: 0 (No Authority Level assigned)
Selections:
0 = No Authority Level assigned (Disabled)
1 = Authority Level 1 assigned
2 = Authority Level 2 assigned
3 = Authority Level 3 assigned
4 = Authority Level 4 assigned
This parameter assigns an authority level to each user. The authority level assigns functions to the user’s PIN and
RF keyfob. See RF Keyfobs on page 78 for a description of RF keyfobs and how to assign them to users.
Authority levels are configured as shown below. See Authority Level Configuration on page 52 to change the
configuration of authority levels.
Authority Level 1 (Master): All options except for Option 5. A user with this authority level configuration
can arm and disarm the system, send reports, and perform all system functions except one-time disarm.
Authority Level 2 (Unlimited): All options except for Option 5 and 14. A user with this authority level
configuration can arm and disarm the system, send reports, and perform all system functions except one-time
disarm and change PINs.
Authority Level 3 (User): All options except for Options 5 and 8 to 15. A user with this authority level
configuration can arm and disarm the system, send reports, but can only perform a limited number of system
functions.
Authority Level 4 (One-Time): All options except 7 to 15. A user with this authority level configuration can
arm and disarm the system (one-time only), send reports, but can only perform a limited number of system
functions and cannot force-arm or bypass zones when arming the system.