DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 113
Bosch Security Systems | 8/04 | 4998153891C
Table 25: Output Function Types (continued)
Digit 1 Digit 2 Function Type Description
0 11 Exit Delay, Entry Delay, Chime Output activates at the start of Exit Delay or Entry Delay. For Steady or
Pulse modes, the output remains activated until Entry or Exit Delay ends.
The output also activates whenever a Chime zone is faulted. The output
does not activate on Chime if Chime Tone is turned off.
0 12 Phone Line Fail Output activates when a Phone Line Fail condition is detected. For
Steady or Pulse modes, the output remains activated until the condition is
cleared. This output works independently of Phone Line Fault
Response Options (page 18).
0 13 Ack Received (any report) Output activates when the acknowledgement for any report is received.
For Steady or Pulse modes, [System Reset] resets. This output type is
event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page
117 for more information.
0 14 AC Fail Output activates when a AC Fail condition is detected. For Steady or
Pulse modes, the output remains activated until the condition is cleared.
0 15 Low or Missing Battery Output activates when a control panel Low or Missing Battery condition
occurs. For Steady or Pulse modes, the output remains activated until the
condition is cleared.
1 0 PO 2 (on-board) Siren
Supervision Fail
Output activates when a Siren Supervision Fail condition is detected. For
Steady or Pulse modes, the output remains activated until the condition is
cleared and the [System Reset] key is pressed.
1 1 Sensor Trouble Monitor Output activates when a Sensor Trouble Monitor condition is detected in
conjunction with the selection made for the Sensor Monitor Time setting.
For Steady or Pulse modes, the output remains activated until the Sensor
Monitor Trouble condition is cleared.
1 2 Duress, [#][4][7] (reset) resets Output activates whenever a Duress PIN is entered. For Steady or Pulse
modes, the output remains activated until user presses [System Reset].
1 3 User Tamper, [#][4][7] (reset)
resets
Output activates on a User Tamper event. For Steady or Pulse modes,
the output remains activated until user presses [System Reset].
1 4 Arming Beeps (for
keyswitch/RF arming)
Disarm/All On/Perimeter Only/Partial On Beeps for keyswitch/RF arming.
1=Off, 2=All, 3=Perimeter Only. Mode and Time parameters do not
apply. This function works in conjunction with Address 1039. See
Global Output Options on page 107. Available for on-board outputs
only.
1 5 Bell Time – Starts on any
Alarm Event. PIN entry Stops.
Activates on Bell Test.
Output activates on any alarm event. Entering PIN terminates Bell Time.
For Steady and Pulse modes, the output remains activated for the
duration programmed in the Bell Time parameter.
1 6 Strobe Activates on Bell Time or output function as programmed. See Strobe
Output Type Options on page 109. PIN entry resets the function.