DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 16
Bosch Security Systems | 8/04 | 4998153891C
Remote Programming Call Back Number
Address: 0181 to 0212
Default: All zeroes (0)
Selections: See Table 4 on page 9
The control panel dials this phone number (or IP address) to begin a RPS remote programming session. See
Network Communication on page 129 for complete network communication programming instructions. Firmware
revision 2.10 or greater is required for network communication.
There are three ways to use this phone number (or IP address):
1. RPS calls the control panel, which answers and determines it is RPS calling, then it disconnects and calls
RPS back.
2. When a user presses [#][4][3], the control panel calls RPS using the phone number (or IP address) entered
here.
3. The control panel can be programmed to use this phone number (or IP address) automatically at test
report time (see Automatic Test {137} Report Options on page 31 for more information).
When entering phone numbers, enter “10” ([1][0] from the keypad) to dial “0”; enter “0” to terminate
the phone number. This does not apply when entering an IP address.