DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 23
Bosch Security Systems | 8/04 | 4998153891C
System Status Report Routing
Address: 0226
Default: 1 (Reports to Destination 1, Events to Log/Printer)
Selections:
0 = No Reports, no Events to Log/Printer
1 = Reports to Destination 1, Events to Log/Printer
2 = Reports to Destination 2, Events to Log/Printer
3 = Reports to Destinations 1 & 2, Events to Log/Printer
4 = Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
5 = No reports, Events to Log/Printer
System Status reports routed by this parameter are marked with an “R” in Control Panel Events and Reporting
Formats on page 138.
Comm Fail 1 (2) reports follow System Status Reports routing. Comm Fail reports for either destination are only
sent if the other destination is the System Status Reports destination. See “Communication Failure (Comm Fail)”
for a description of the Comm Fail event, and “Dialing Attempt Tables” for the dialing sequence in the DS7200V2
Installer’s Guide (P/N: 4998153893).
Call for Service Interval
Address: 0227, 0228
Default: 0,0
Selections: 00 to 99
This parameter determines the interval in weeks (7 days), (00 to 99). For example, if you enter 0,2, the control
panel waits 2 weeks (14 days) between displaying service messages.
At this interval, the keypad displays a “Call for Service” fault and/or sends a Call for Service {37} report (per the
Call for Service/System Inactive Options parameter). The display appears at all keypads in all areas. The report is sent
for Area 1 only and follows System Status Report routing.
Press [System Reset] to reset the fault in the area to which the keypad is assigned. Enter 0,0 to disable this
parameter.
System Inactive Interval
Address: 0229, 0230
Default: 0,0
Selections: 00 to 99
If an area is not armed (All, Perimeter Only or Partial On) in this interval, the control panel sends a System
Inactive {136} Report for that area. A ‘System Inactive’ Display is optional, see Call for Service/System Inactive
Options on page 24 for more information.
The interval is in weeks (00 to 99). Enter 0,0 to disable this parameter.