Bosch DS7200V2-EXP Podręcznik Użytkownika Strona 52

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 156
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 51
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 52
Bosch Security Systems | 8/04 | 4998153891C
4.4 User Interface
4.4.1 Authority Level Configuration
The Authority Level determines which functions are available to system users. Each user is assigned an authority
level. Use the parameters in this section to configure each of the four authority levels available in the control
panel.
Authority Level Option 1: All On Arming
Address: 0364
Default: 15
Selections: 0 to 15
Enter This Data Digit to Select Options
Authority Level Option 1: All On Arming 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No PIN Required (Quick Arm)
Assign to Authority Level 1
• • • • • • • •
Assign to Authority Level 2
Assign to Authority Level 3
• • • • • • • •
Assign to Authority Level 4
• • • • • • • •
This parameter enables/restricts the following functions by authority level:
[#][1]: All On with Entry Delay
[#][1]: All On with Entry Delay, No Exit Tone*
[#][1]: All On with No Entry Delay
[On] Key: All On with Entry Delay
[On] Key: All On with Entry Delay, No Exit Tone*
[On] Key: All On with No Entry Delay
* Exit Time is doubled (up to 254 sec) when arming the system All On with Entry Delay, Silent (no Exit Tone).
If a PIN is required and not entered, the system asks for one after the function is entered.
To enable the “Quick Arm” feature, set Authority Level Option 1 to 0. A user PIN entry is not required for All
On arming.
Przeglądanie stron 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 155 156

Komentarze do niniejszej Instrukcji

Brak uwag