DS7200V2-EXP | Expert Programming Guide | 5. Reference Materials EN | 146
Bosch Security Systems | 8/04 | 4998153891C
Table 31: Control Panel Events and Reporting Formats (continued)
Event Event as shown in
Control Panel Log
SIA Report Contact ID
Report
Event Description Zone Types
Linked to Event
RPS
Event
Group
Status
Report
158 Walk Test Start TS Test Start
607 Walk Test
Mode
Walk Test started with Walk Test
key sequence ([#][4][4]).
11
159 Walk Test End TE Test End
607 Walk Test
Mode
Walk Test ended by user or timed
out.
11
160 Siren Trouble YA Bell Fault
320 Sounder
Relay
Trouble condition detected on PO
2 configured as supervised siren
output.
12 R S
161 Siren Restoral YH Bell Restored
320 Sounder
Relay
Trouble condition on supervised
siren output cleared.
12 R S
162 Grnd Fault
IA Equipment
Failure Condition
310 Ground
Fault
Ground fault detected on panel’s
sensor loops, Option Bus, or Aux
power outputs.
12 R S
163 Grnd Fault,Rstl
IR Equipment Fail
Restoral
310 Ground
Fault
Ground fault condition cleared. 12 R S
164 First Open
OP Opening
Report
400
Open/Close
Panel is configured for multiple
area first to open, last to close
function. See Arming Options 2 on
page 38. First area has opened.
10
165 Last Close
CL Closing
Report
400
Open/Close
Panel is configured for multiple
area first to open, last to close
function. See Arming Options 2 on
page 38. Last area has closed.
10
166 AltCom Cond
NC Network
Condition
350
Communication
Trouble
Trouble detected on Alternate
Communication network.
12 R S
167 AltComm Fail
NT Network
Failure
350
Communication
Trouble
Network failure detected on
Alternate Communication network.
12 R S
168 AltComm Rstrl
NR Network
Restoral
350
Communication
Trouble
Network communication resumed
on Alternate Communication
network.
12 R S
169 Reserved
170 Reserved
171 Reserved
172 Reserved
173 Rstrl,Swinger
BU Burglary
Unbypass
575 Swinger
Shunt
Restoral from Swinger Shunt. Any zone type 8
174 Rstrl,Fire,Miss Local Event Only
Local Event
Only
Restoral from Fire Missing. Local
event, no report.
1- Fire
2- Fire with
Alarm
Verification
7
175 Rstrl,Alarm,Miss Local Event Only
Local Event
Only
Restoral from Missing, Non-Fire
zones. Local event, no report sent.
Any non-fire
zone type
8
176 Rstrl,Trble,Miss Local Event Only
Local Event
Only
Restoral from Fault (Trouble), Non-
Fire zones. Local event, no report.
Any non-fire
zone type
8
177 Rstl,Low Signl Local Event Only
Local Event
Only
Restoral from Alternate
Communication Low Signal
Strength event.
12 R S
178 UnBypss,Fire,RPS FU Fire Unbypass
571 Fire
bypass
Bypass on Fire zone type cleared
using RPS (un-bypass).
1- Fire
2- Fire with
Alarm
Verification