Bosch DS7200V2-EXP Podręcznik Użytkownika Strona 130

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 156
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 129
DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 130
Bosch Security Systems | 8/04 | 4998153891C
Port Number for IP Address 1 (2) for Destination 1 (2)
Address:
Port Number for IP Address 1, Destination 1: 3886 to 3890
Port Number for IP Address 2, Destination 1: 3891 to 3895
Port Number for IP Address 1, Destination 2: 3896 to 3900
Port Number for IP Address 2, Destination 2: 3901 to 3905
Default: 07700
Selections: 0 to 65,535
Use the addresses listed above to associate the ARC’s IP address to a specific port number for network
communication.
This parameter uses five addresses for each routing destination to enter the port number:
First Address: Enter the 10,000’s value (this value is multiplied by 10,000)
Second Address: Enter the 1,000’s value (this value is multiplied by 1,000)
Third Address: Enter the 100’s value (this value is multiplied by 100)
Fourth Address: Enter the 10’s value (this value is multiplied by 100)
Fifth Address: Enter the 1’s value (this value is added to the other values)
The following example shows how to enter 55555 as the port number for IP Address 1, Destination 1:
[5 x 10,000] + [5 x 1,000] + [5 x 100] + [5 x 10] + 5 = Port Number 55,555
Remote Programming Callback Number
Address: 0181 to 0212
Default: All zeroes (0)
Selections: 000.000.000.000 to 255.255.255.255 (see Table 30 on page 129)
An IP address can be used to begin a remote programming session. See IP Address 1 (2) for Destination 1 (2) to
enter an IP address. See Remote Programming Call Back Number on page 16 for more information.
Address 3886 Entry
Address 3887 Entry
Address 3888 Entry
Address 3889 Entry
Address 3890 Entry
Przeglądanie stron 129
1 2 ... 125 126 127 128 129 130 131 132 133 134 135 ... 155 156

Komentarze do niniejszej Instrukcji

Brak uwag