Tamper Reset/Arming Options
Address: 3408
Default: 3
Selections: 0 to 3
Enter This Data Digit to Select Options
Tamper Reset/Arming Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Tamper Reset/Arming Options
Allow User Reset of Tampers/Troubles
• •
Allow Force Arming of Tampers/Troubles
Reserved
Reserved
This parameter enables user reset of a tamper or trouble condition and force arming of the control panel when a
tamper or trouble condition exists.
Allow User Reset of Tampers/Troubles: If enabled, this option allows a user with the appropriate authority
level to reset tamper and major trouble conditions. Enable Authority Level Option 9: System Functions 1 (page 57)
and Authority Level Option 10: System Functions 2 (page 58) for each user who can reset tamper and trouble
conditions.
The following conditions are treated as major trouble conditions:
24-hour zone missing (DX2010 Data Bus device missing)
Controlled zone missing (DX2010 Data Bus device missing)
Low or missing system battery
Telephone line fail (if programmed for user reset)
Alternate communication path fault (if programmed for user reset)
24-hour zone trouble (zone programmed for trouble, not alarm)
Controlled zone trouble (zone programmed for trouble, not alarm)
Allow Force Arming of Tampers/Troubles: If enabled, this option allows a user with the appropriate
authority level to force arm the control panel when a tamper or major trouble condition exists. Enable
Authority Level Option 7: Force Arm/Bypass (page 56) for each user who can force arm the system when a tamper
or trouble condition occurs. If the tamper or trouble is zone-related, the zone function configuration must
have the "Can Be Bypassed or Force Armed" options enabled (see Options 2, Zone Function ## on page 99).