DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 19
Bosch Security Systems | 8/04 | 4998153891C
4.2.4 Global Reporting Options
These parameters configure the reporting for all areas, all zones, and all users.
Global Reporting Options
• Address: 0221
• Default: 1
• Selections: 0, 1, 3, 5, 7, 9, 11, 13, 15
Enter This Data Digit to Select Options
Global Reporting Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Local Only
•
Enable Reporting
•
•
•
•
•
•
• •
Extend Handshake
•
•
•
•
Delay Alarm Output
•
•
• •
Burg Alarm after Two Failed Attempts
•
•
• •
• Local Only: The control panel sends no reports.
• Enable Reporting: If this option is enabled, the control panel sends reports as programmed provided that at
least one phone number (or IP address) has been programmed for at least one Routing Destination (see Phone
Number 1 (2) for Destination 1 (2) on page 9). Reporting options can be enabled and disabled in other
parameters. See Open/Close Reporting Options on page 39, and Area # Opening {89-96}/Closing {42-67} Reporting
Options on page 49 for more information.
• Extend Handshake: If this option is enabled, the control panel finishes dialing the ARC receiver and waits
for a ‘handshake’ tone from the receiver. The handshake is the first thing the receiver sends after answering
the phone. Typically each reporting format the receiver supports has its own handshake tone. If a receiver
supports several formats, it sounds the handshake tones one at time. Choosing this option extends the time the
control panel waits for a handshake from the ARC receiver from 45 to 60 sec.
Do not change the Extend Handshake option unless advised by Bosch Technical Service.
• Delay Alarm Output: If this option is enabled, the control panel delays burglary alarm output until
communication to the ARC receiver is complete or there are two failed dialing attempts. The delayed alarm
output functions are 1|8, 1|9 and 1|10 (see Table 25 on page 112 for descriptions of output function types). Bell
Time is not delayed, and begins at the alarm event. If Bell Time is set at three min. or less, alarm output
delayed by this option may be very short (less than 1 minute), or the alarm output may not activate at all. See
Output Parameters on page 107 for a complete description of output functions. The keypad sounder is not
delayed by this option.
Disable the Alarm Event Abort option when using the Delay Alarm Output option. See Options 1, Zone
Function ## on page 95.