DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 8
Bosch Security Systems | 8/04 | 4998153891C
4. Control Panel Programming
The contents of this section are organized as in Remote Programming Software (RPS).
This section covers all of the available programming parameters. The programming section in the
DS7200V2 Installer’s Guide (P/N: 4998153893) covers the programming parameters only available
when the control panel is in the Installer Programming Mode.
This section contains programming parameter information pertaining to the DS7240V2 and DS7220V2 Control
Panels. Settings for parameters are stored at one or more addresses. For an overview of how to program the
control panel from a DS7447E or DS7447V2 Text Keypad, see Keypad Programming on page 5.
Numbers enclosed in braces, (for example, {137}) that appear throughout this document refer to the control
panel’s event numbers. See Control Panel Events and Reporting Formats on page 138 for event descriptions.
The default Installer PIN is 9876. The default PIN for User 1 is 1234. All other user PINs are not programmed by
default. See Installer PIN on page 63 and PIN, User # on page 65 for more information.
4.1 Understanding the Parameter Option Charts
The programming section of this document uses charts like the one below to identify the available selections for
option parameters.
Enter This Data Digit to Select Options
Phone Line Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Phone Line Options
Do Not Wait for Dial Tone
• •
• •
“R” Function/Three-way Calling
Reserved
Phone Line Fault Requires Reset
• • • •
The first option usually disables or turns off all the other options.
The data digit values (labeled 0 to 15 under the “Enter This Data Digit to Select Options” heading) are displayed
across the top of the table. Each data digit is ties to options by a “.” To select an option, enter the corresponding
data digit value at the address programming prompt.
The option parameter’s default selection is listed above the table in bulleted form along with the option’s address
and selection range. The numbered cell that corresponds with the option’s default setting is blackened to provide a
quick visual reference. For example, the cell labeled “10” in the example above is this option parameter’s default.
Columns that are grayed out are reserved settings and should not be selected.