DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 125
Bosch Security Systems | 8/04 | 4998153891C
4.8.2 RS-232 Module Configuration
The following parameters apply to the DX4010i and DX4010 RS-232 Serial Interface Modules.
Output Configuration Options
Address: 1253
Default: 0 (Disabled)
Selections:
0 = Disabled(no RS-232 module connected)
1 = RS-232 Log Output using Internal Codes
2 = RS-232 Log Output using PC Compatible Codes
Set the RS-232 module to Data Bus Address 250. See “DX4010i/DX4010 Addressing” in the DS7200V2 Installer’s
Guide (P/N: 4998153893) for information.
This parameter only applies when the RS-232 module is used for RS-232 serial output. It does not apply if the
DX4010 is used for direct-connect remote programming.
RS-232 Log Output using Internal Codes: If enabled, this option outputs the events using the internal
keypad character codes. Non-standard characters may not print correctly.
RS-232 Log Output using PC Compatible Codes: If enabled, this option outputs the events using PC
compatible character codes. Non-standard characters are mapped to the closest matching character for display
or printing.
If you connect a printer to the RS-232 module and get unexpected results, check the module output
configuration (Address 1253), baud rate configuration (Address 1254) and parity/flow control/stop bit
configuration (Address 1255) for proper settings.
Baud Rate Options
Address: 1254
Default: 2 (2400 bps)
Selections:
1 = 1200 bps
2 = 2400 bps
3 = 4800 bps
4 = 9600 bps
5 = 14400 bps
This parameter identifies which baud rate the RS-232 module should use for communication.
If you connect a printer to the RS-232 module and get unexpected results, check the module output
configuration (Address 1253), baud rate configuration (Address 1254) and parity/flow control/stop bit
configuration (Address 1255) for proper settings.