DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 81
Bosch Security Systems | 8/04 | 4998153891C
Table 13: Location Configuration Parameters (continued)
Location Parameters
These columns show the addresses and
defaults for each of the four location
parameters. These parameters configure
each location. Shaded cells only apply to the
DS7240V2.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter tells the
control panel where to find the sensor loop (or transmitter) status for each Location.
Location Device Zone
Function
Area Zone # On-board
Device = 1
DX2010
1
Device = 2
DX2010
1
Doubled
Device = 3
RF Rcvr 1
1,2
Device = 4
RF Rcvr 2
1,2
Device = 5
DACM
3
Device = 6
(optional)
21 0806
(0)
0807
(0)
0808
(1)
0809, 0810
(2,1)
DBus Adr 103
Loop 5
DBus Adr 106
Loop 5; 2.2 kΩ
DBus Adr 50
Xmitter 21
DBus Adr 51
Xmitter 21
DACM
22 0811
(0)
0812
(0)
0813
(1)
0814, 0815
(2,2)
DBus Adr 103
Loop 6
DBus Adr 106
Loop 6; 2.2 kΩ
DBus Adr 50
Xmitter 22
DBus Adr 51
Xmitter 22
DACM
23 0816
(0)
0817
(0)
0818
(1)
0819, 0820
(2,3)
DBus Adr 103
Loop 7
DBus Adr 106
Loop 7; 2.2 kΩ
DBus Adr 50
Xmitter 23
DBus Adr 51
Xmitter 23
DACM
24 0821
(0)
0822
(0)
0823
(1)
0824, 0825
(2,4)
DBus Adr 103
Loop 8
DBus Adr 106
Loop 8; 2.2 kΩ
DBus Adr 50
Xmitter 24
DBus Adr 51
Xmitter 24
DACM
25 0826
(0)
0827
(0)
0828
(1)
0829, 0830
(2,5)
DBus Adr 104
Loop 1
DBus Adr 107
Loop 1; 3.65 kΩ
DBus Adr 50
Xmitter 25
DBus Adr 51
Xmitter 25
DACM
26 0831
(0)
0832
(0)
0833
(1)
0834, 0835
(2,6)
DBus Adr 104
Loop 2
DBus Adr 107
Loop 2; 3.65 kΩ
DBus Adr 50
Xmitter 26
DBus Adr 51
Xmitter 26
DACM
27 0836
(0)
0837
(0)
0838
(1)
0839, 0840
(2,7)
DBus Adr 104
Loop 3
DBus Adr 107
Loop 3; 3.65 kΩ
DBus Adr 50
Xmitter 27
DBus Adr 51
Xmitter 27
DACM
28 0841
(0)
0842
(0)
0843
(1)
0844, 0845
(2,8)
DBus Adr 104
Loop 4
DBus Adr 107
Loop 4; 3.65 kΩ
DBus Adr 50
Xmitter 28
DBus Adr 51
Xmitter 28
DACM
29 0846
(0)
0847
(0)
0848
(1)
0849, 0850
(2,9)
DBus Adr 104
Loop 5
DBus Adr 107
Loop 5; 3.65 kΩ
DBus Adr 50
Xmitter 29
DBus Adr 51
Xmitter 29
DACM
30 0851
(0)
0852
(0)
0853
(1)
0854, 0855
(3,0)
DBus Adr 104
Loop 6
DBus Adr 107
Loop 6; 3.65 kΩ
DBus Adr 50
Xmitter 30
DBus Adr 51
Xmitter 30
DACM
31 0856
(0)
0857
(0)
0858
(1)
0859, 0860
(3,1)
DBus Adr 104
Loop 7
DBus Adr 107
Loop 7; 3.65 kΩ
DBus Adr 50
Xmitter 31
DBus Adr 51
Xmitter 31
DACM
32 0861
(0)
0862
(0)
0863
(1)
0864, 0865
(3,2)
DBus Adr 104
Loop 8
DBus Adr 107
Loop 8; 3.65 kΩ
DBus Adr 50
Xmitter 32
DBus Adr 51
Xmitter 32
DACM
33 0866
(0)
0867
(0)
0868
(1)
0869, 0870
(3,3)
DBus Adr 105
Loop 1
DBus Adr 107
Loop 1; 2.2 kΩ
DBus Adr 50
Xmitter 33
DBus Adr 51
Xmitter 33
DACM
34 0871
(0)
0872
(0)
0873
(1)
0874, 0875
(3,4)
DBus Adr 105
Loop 2
DBus Adr 107
Loop 2; 2.2 kΩ
DBus Adr 50
Xmitter 34
DBus Adr 51
Xmitter 34
DACM
35 0876
(0)
0877
(0)
0878
(1)
0879, 0880
(3,5)
DBus Adr 105
Loop 3
DBus Adr 107
Loop 3; 2.2 kΩ
DBus Adr 50
Xmitter 35
DBus Adr 51
Xmitter 35
DACM
36 0881
(0)
0882
(0)
0883
(1)
0884, 0885
(3,6)
DBus Adr 105
Loop 4
DBus Adr 107
Loop 4; 2.2 kΩ
DBus Adr 50
Xmitter 36
DBus Adr 51
Xmitter 36
DACM
37 0886
(0)
0887
(0)
0888
(1)
0889, 0890
(3,7)
DBus Adr 105
Loop 5
DBus Adr 107
Loop 5; 2.2 kΩ
DBus Adr 50
Xmitter 37
DBus Adr 51
Xmitter 37
DACM
38 0891
(0)
0892
(0)
0893
(1)
0894, 0895
(3,8)
DBus Adr 105
Loop 6
DBus Adr 107
Loop 6; 2.2 kΩ
DBus Adr 50
Xmitter 38
DBus Adr 51
Xmitter 38
DACM
39 0896
(0)
0897
(0)
0898
(1)
0899, 0900
(3,9)
DBus Adr 105
Loop 7
DBus Adr 107
Loop 7; 2.2 kΩ
DBus Adr 50
Xmitter 39
DBus Adr
51Xmitter 39
DACM
40 0901
(0)
0902
(0)
0903
(1)
0904, 0905
(4,0)
DBus Adr 105
Loop 8
DBus Adr 107
Loop 8; 2.2 kΩ
DBus Adr 50
Xmitter 40
DBus Adr 51
Xmitter 40
DACM
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional. See
DACM Configuration on page 135 for instructions on integrating the DACM door contact into the security system.