D7212GV2 | Program Entry Guide | 6.0 GV2AUX EN | 121
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
The external modem is connected to the D9133DC
Direct Connect Programming Module that is
connected to the SDI bus using SDI Address 88. Refer
to Figure 9 on page 121. A standard serial cable is
required to connect the D9133DC to the external
modem.
If you are using an external modem for RPS
communications, the enhanced
communications and RPS functions using a
NIM are disabled.
Figure 8: Com Port Selection within HyperTerminal
Figure 9: External Modem Connection
P3
P2
1 2 4 8
SER RX TX RX TX BUS
SDI
PWR
SDI
A
SDI
B
SDI
COM
D9133DC
EARTH GROUND
COMMON
RELAY A
RELAY B
RELAY C
+ AUX POWER
CLASS 2 TRANS FORMER
16.5 VAC 40 VA 60 Hz
Model D1640
Internally Fused - Do not short
Requires U nswitched Out let
Do not share with other equipment
GROUND FAULT DE TECT
Enabled
Disabled
Digital Alarm Communic ator Transmitter
D7212GV2 Control Panel is UL Listed for Household Fire Alarm, and Central Station, Local,
Police Station Connect, Household Burglar Alarm an d Encrypted Line Secu rity when
communicating via a networ k.
System i s Intended To Be C hecked By A Qualified Techni cian At Least Every 3 Years.
The types of initiating circuits for which the control panel has been approved are A, M, W, SS.
VOLTAGE RANGES
Open 3.7 - 5.0 VDC
Normal 2.0 - 3 .0 VDC
Short 0.0 - 1.3 VDC
Reset P in
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED POWER +
YELLOW DATA BUS A
GREEN DATA BUS B
BLACK COMMON
ZONEX OUT 1
ZONEX IN 1
N.F.P.A.
Style 4.0
Signaling
Line
Circuits
F01U003800-01
1211 13
Point 1 Poi nt 2
1514 16
Point 3 Point 4
1817 19
Poi nt 5 Point 6
2120 22
Point 7 Point 8
LEDs Off When Normal
Charging Status
Low Battery - 12.1 VDC
YEL
RED
10.2 VDC - Ba ttery L oad She d
This equ ipment should be installed in acc ordance wi th the NFPA 70 (Natio nal Electrical Code)
and NF PA 72 (National Fire Alar m Code) fo r Local, Central Station, Remote S tation, Proprietary a nd
Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction
(National Fire Protection Association, Battermarch Park, Quincy, MA 02269). Printed information
describing proper installation, operation, testing, maintenance, evacuation planning and repair
service is to be provided with this equipment.
D7212GV2
NOT USED
26
25
NOT USED
ZONEX POWE R +
24
ZONEX COMMO N
23
SDI Connector
Refer to
D7212GV2 A pproved Applicatio ns Compliance G uide
(P/N: F 01U003806)
For System Wiring Diagram, Issue A and for Compatible Smoke Detectors
BATTERY NEGATIVE ONLY
BATTERY POSITIVE ONLY
CAUTI ON:
Avoid damage to Panel.
Do not con nect 24 V t o terminals .
Maximum charging current 1.4 A
PHONE
LED
RED
ON wh en
communicating
OFF when i dle
PHONE LINE SEIZED
TIP
RING
TELCO C ORD
MODEL D 161
CAUTION:
Refer to
D7212GV2 Operation and Installation Guide
POWER SUPPLY REQUIREMENTS
The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all
Accessory Devices. For System L oading, refer to
D7212GV2 Operation and
Installation Guide
(P/N: F01U003805) .
All external conne ctions except Terminal 5 (battery positi ve) are inherently power
limited. Requirements for battery standby time might reduce allowable output.
(P/N: F01U003805) f or Power Requirements relat ing to Terminals 6 and 7 .
WAR NIN G!
Multi-Battery installation requires
Model D122/D122L Dual Battery
Harness. Improper installation can
be a fi re hazard.
Battery: Replace every 3 to
5 years with on e or two Model
D126 or D1218 12V Lead Acid
Batteries.
GRN
Point 8
S3 Option
Closed = 1K
W
EOL
Normal Operation
Open =AB- 12 UL
Bell Box 220 K
W
D5200/D5360
PROG CONN
Incorrect wiring will
damage this equipment.
Suitable for dry indoor
use only.
Devices powered b y the
AUX power output must
be supervised.
Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2000:
UL Listed an d Classified control un it Model D9412GV2 , D7412GV2, or D 7212GV2;
UL Listed a nd Classified ke ypad Model D 1256, D1257, D1260, D1255, D1255R, or D125 5RW;
UL Listed Local Bell
PROGRAMMAB LE
ALARM OUTPUTS
Ter min al s
SWITCHED AUX
and
67
Term ina l
8
1 - PC running Remote Programming Software (RPS)
2 - Modem
3 - PSTN
4 - D7212GV2 Control Panel
5 - Standard serial cable
6 - SDI bus