D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 61
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Service Walk
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
33 Service Walk Test (Menu function only)
Use this function to Walk Test all 40 points in the
entire control panel regardless of the
P## Type
.
The Service Walk Test function must be
enabled in the Function List to access the
Service Walk Test.
Default Text
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
34 Default Text [COMMAND][5][7]
Determining the armed state of an area using the
programmed custom text might be difficult. Use this
function to switch temporarily to the control panel
default text, shown on the program record sheet.
Change Skeds
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
35 Change Skeds [COMMAND][5][2]
Execute this panel-wide function from any keypad
assigned to an area where the user has authority. Use
this function to change the
S## Time
from the keypad
to make adjustments to Skeds.
Invisible Walk Test
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
36 Invisible Walk Test (Menu function only)
This function allows a user with the
L## Invisible
Walk Test
authority to test invisible interior or
perimeter controlled points that are within the scope of
the keypad, without sending reports to the central
station. Invisible points must have the
P## Invisible
Pt
function programmed Yes.
Custom Functions
C Function 128 [through 131]
Default: E
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
128 through
131
Enable Custom
Functions 128
through 131
(Menu function only)
When enabled, Custom Function determines if a
passcode is required when accessing a custom function
from the menu list. ENTER PASSCODE (or Enter
Passcode + Enter Key on the D1260) appears
when this function is pass-code protected. If a
command within the Custom Function is pass-code
protected, the keypad displays ENTER PASSCODE (or
Enter Passcode + Enter Key on the D1260)
and waits for the user to enter a valid passcode before
proceeding with the rest of the Custom Function. If a
passcode is not entered within 10 sec, the Custom
Function times out and the display returns to idle text.
2.11.4 Authority Level Selections
Use Section 2.11.4 Authority Level Selections on page 61
to determine which Authority Level can access keypad
functions that are pass-code protected. Selecting
Enable items in the Authority Level section is not
necessary if the keypad function is disabled or
enabled. Each individual function has two selections
you can use for the authority level you are
programming.
Press the [SPACE] bar to scroll through the selections.
Press [ENTER] when the correct selection appears in
the display.
Table 25: Authority Level Selections
Authority
Level
Description
Blank
Disabled: This function is not
authorized for the user who is
assigned this authority level.
E
Enabled: This function is authorized
for the user who is assigned this
authority level.