D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 62
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Authority Level
Default: 1
Selection:
1 to 14
Enter the number of the authority level you want to
program. Authority Level 15 (Service Passcode) cannot
be edited.
To determine the L## default values on
pages 62 through 69, refer to the User
Interface section for the GV2MAIN Handler
in the program record sheet.
L## Disarm
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name
1 Disarm
Use the disarming function to disarm areas that are
master armed or perimeter armed. If enabled, the
following disarming choices are available to the user
with this authority:
• DISARM ALL: Disarms all areas within the
CC#
Scope
of the keypad being used by accessing the
Function Menu and the authority level of the user
performing the function.
• DISARM AREA: Disarms only the displayed
area.
Many options are available for arming and
disarming. Selecting an option depends on
A# Area Type and CC# Scope. Read the
definitions of area type in Section 2.9 Area
Parameters on page 5 and CC# Scope in
Section 2.10.1 Keypad (Command
Center) Assignment on page 46.
L## Master Arm Delay
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
2 Master Arm Delay [COMMAND][1]
Master arms areas based on the
CC# Scope
of the
keypad using an exit delay time.
When this item is accessed through the Function List,
Master Arm All allows the user to arm all areas
according to the authority level of the user and within
the
CC# Scope
of the keypad using an exit delay
time.
Arm Area arms only the area displayed. If
COMMAND 1 is used, it arms only the area where
the keypad is assigned.
L## Mstr Arm Inst
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
3 Master Arm
Instant
[COMMAND][1][1]
This authority level permission allows a user to
execute the Master Arm Inst function. Refer to Mstr
Arm Inst on page 56.
Arm Area arms only the area to which the keypad is
assigned.
If COMMAND 11 is used, it arms only the area where
the keypad is assigned.
Use COMMAND 11 carefully because all
Perimeter and Interior points become
Instant Armed.
L## Perim Instant
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
4 Perimeter Instant
Arm
[COMMAND][2]
Instant arm all Perimeter points, including Delayed
points, only in the area where the keypad is assigned.
Komentarze do niniejszej Instrukcji