D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 36
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
A# Area Type
Default: Regular
Selection:
Regular, Master, Associate, or Shared
Regular Arms or disarms as an independent area.
Master Does not allow arming for this area unless all associate areas with the same A# account number
are master exit delay armed or master armed. CHK AREA displays if the associate areas are not
armed. Exception: RPS allows master areas to be armed without all associate areas being in the
armed state.
A master area can be disarmed regardless of the armed state of the other areas in the account.
Multiple master areas can be programmed in a single account.
CC# Scope affects master arming.
Area: When arming a master area that has CC# Scope set to Area for all
keypads, all associate areas within the same account must first be armed
independently by other means.
Panel Wide or Account Wide: When arming a master area from a keypad with
CC# Scope set to Panel Wide or Account Wide, all associate areas enters
exit delay as soon as the master area is armed. If there is a shared area within
the same account, it begins its exit delay after all associate areas are armed.
Using the arming sked (S## Function 1) requires that you first use an arming
sked to arm the associate areas before using an arming sked to arm the
master area. Arming master areas with RPS, Keyswitch, or Auto Close
parameters (refer to Open/Close Options) occurs before all associate areas
are armed
Associate Allows arming and disarming regardless of the armed state of the other areas with the same A#
account number. Use this area type with a master area and associate it by using the same account
number.
Keypads assigned to associate areas, when used with shared areas, must
have CC# Scope programmed.
Shared Shared areas cannot be armed using a passcode, key switch, token or card, sked, or RPS.
The scope of all associate areas must include the shared area(s) in order to view
faulted points.