D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 51
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
CC# Scroll Lock
Default: No
Selection:
Yes or No
Yes Prevents the idle system status text
from scrolling automatically.
Requires user intervention to
advance.
No Allows the idle system status text to
scroll automatically without user
intervention.
Use this parameter to enable a special non-scrolling
option for the idle system status display text on a
keypad. This keypad mode requires the user to press
PREV or NEXT on the keypad to unlock the display
and begin scrolling through the system status displays.
CC# Menu Key Lock
Default: No
Selection:
Yes or No
Yes
If set to Yes, the user is prompted to
enter a passcode after pressing the
Menu key on the keypad. The items
programmed in the Menu List for this
specific keypad are filtered by the
user’s authority level. Only those
items in the menu list for which the
user has authority appear.
No
If set to No, when the user presses
the Menu key, all items that are
programmed in the Menu List for the
Command Center Address (Keypad
Address) appear, regardless of the
user’s authority level.
Determines if the Menu Key, when pressed, requires a
passcode to access the functions.
If this parameter is set to Yes, users must
enter a passcode after pressing the Menu
key. When the passcode is validated, only
those functions for which the user has
authority appear in the list. If a function in
the Menu List is pass-code protected (refer
to Keypad Functions in Section 2.11.2
User Interface on page) the user does not
need to enter the passcode again.
CC# Abort Display
Default: Yes
Selection:
Yes or No
Yes This keypad shows the Alarm Aborted
message for all aborted alarms within
its scope.
No
This keypad does not show the Alarm
Aborted message for all aborted
alarms within its scope.
This parameter enables or disables the ALARM NOT
SENT message when an alarm is aborted before
transmission occurs.
For SIA CP-01 Compliance
CC# Abort Display
can be set to Yes or No.
CC# Cancel Display
Default: Yes
Selection:
Yes or No
Yes This keypad shows the Cancel Report
Sent message for all canceled alarms
within its scope.
No
This keypad does not show the Cancel
Report Sent message for all canceled
alarms within its scope.
This parameter enables or disables the CANCEL RPT
SENT display message when an alarm is canceled after
transmission occurs. To show this message, Cancel
Report must be set to Yes. Refer to
Cancel Report
on
page 31.
For SIA CP-01 Compliance
CC# Cancel Display
can be set to Yes or No.