Bosch D7212GV2 Przewodnik Instalacji Strona 35

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 140
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 34
D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 35
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Table 21: Verify Time
Verification Point
Activiation
Verify Time/Reset
Sensors
Power removed,
ignore activity
60 sec
Confirmation
Generate alarm if
additional activity
received.
Restart Alarm
Verification Cycle if
an Alarm
Verification point
activates.
Example: Total
Cycle time 80 sec
20 Sec 60 Sec
A# Duress Enable
Default: No
Selection:
Yes or No
Yes Enable Duress alarm for this area.
No Disable Duress alarm for this area.
Refer to
Duress Type
in Section 2.8 Miscellaneous on
page 31 for an explanation of duress.
The passcode you normally use for
duress is not valid in an area with A#
Duress Enable set to No.
If a passcode with the appropriate
L# Disarm authority is used to duress
disarm an area with A# Duress Enable
set to No, NO AUTHORITY appears in
the display. Also, if the keypad display is
moved to an area with A# Duress
Enable set to No using
[COMMAND][5][0], a valid duress disarm
passcode does not send a duress report.
For SIA CP-01 Compliance:
A# Duress Enable
must be set to Yes.
Przeglądanie stron 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 139 140

Komentarze do niniejszej Instrukcji

Brak uwag