Figure 8.20: Communication Setting
b. Click “New Customer” in “Customer” to create customer. Enter relevant customer
information in the “Customer Information” tab page. The “Customer Number” must be
entered. The IP address and port number of the alarm control panel are the IP address
and port number of the communication module 1 installed in the alarm control panel, and
will be used when the alarm control panel uses fixed IP and port number. If the fixed IP
address and port number are not known, after the UDP data packet transmitted by the
alarm control panel is received and the SUBSCRIBER NUMBER of receiver 1 has been set
in the “Control Panel Configuration” tab page, please directly click the connection in the
“connection” tab page. The prompt information will recommend the SUBSCRIBER
NUMBER the alarm control panel received the last time and its IP address and port
number.
Under DHCP environment, it is not necessary to set “Alarm Control Panel IP Address” and
“Alarm Control Panel Port Number”.
AMAX panel 4000 / AMAX panel 4000
EN
Configuration | en 101
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112