Siren / PO 1+2 Supervision
Address 0140 Address Default
0 = disabled, 1 = PO1 enabled, 2 = PO2 enabled, 3 =
PO1+2 enabled
0140 0
VDS-A EN=3
Keypad 2 Button Alarm
Address 0141 Address Default
0 = disabled, 1 = enabled 0141 0
Phone Line Monitor
Address 0142
Address Default
0 = disabled, 1 = enabled 0142 0
VDS-A
EN=1
Beep For Warning Devices
Address 0143
Address Default
0 = disabled, 1 = enabled 0143 1
Ring Count
Address 0144
Address Default
1 - 13 = Number of rings until the control panel responds
14 = Call the control panel and allow the phone to ring no
more than twice and hang up. Wait a minimum of 8 sec
and call the control panel again. The control panel
answers on the first ring.
15 = Call the control panel and allow the phone to ring no
more than four times and then hang up. If you call again
within 45 sec, the control panel answers the call on the
first ring.
0 = Panel does not answer
0144 14
Remote Programming
Address 0145
Address Default
0 = disabled, 1 = enabled 0145 1
VDS-A=0
Callback Telephone Number
Address
0146 - 0161 Address Default
See Telephone Programming Parameters 0146 - 0161 15
110
en | Programming
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH