Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
0113 1
Anti-replay for Receiver (0 = Disabled, 1 = Enabled) 0114 1
EN=1
Acknowledge Wait Time for Receiver (05 - 99 seconds) 0115 - 0116 05
Network Polling Time for Receiver (001 - 999 minutes) 0117 - 0119 001
Notice!
Enter telephone number when the Contact ID or SIA is selected; enter IP address and port
number when the Conettix IP is selected. Anti-replay for Receiver, Acknowledge Wait Time for
Receiver and Network Polling Time for Receiver are valid only when using Conettix IP.
Consequences
Setting Telephone Number
For telephone number programming, See Telephone Programming Parameters
Setting IP Address and Port Number
The IP address is programmed with the 17 digits: Digits 1 - 12 for the IP address of the
receiver; 13 - 17 for the port.
It is not necessary to enter dots in programming, but 0 must be entered ahead of the digit to
make up 3 digits when each IP address unit is fewer than 3 digits. 0 must be entered ahead of
the digit to make up 5 digits when the port is fewer than 5 digits.
Example:
Receiver IP address 128.73.168.7, port 7700, should be made as: 128 073 168 007 07700
Dual IP Settings
Option
Address Default
0 = 1 IP module, 1 = 2 IP modules 0120 1
Notice!
Dual IP Settings are valid only when used in the Conettix IP format. This programming option
is valid for B426 and ITS-DX4020-G modules. ITS-DX4020-G cannot be set as No. 2 IP module.
Module Address
ITS-DX4020-G module or B426- module 1 134
B426 module 2 250
System Reporting
Option Address Default
Zone Status Restore Report 0121 6
AWAY Arming / Disarming Report 0122 6
EN=1/5/6/7
STAY Arming / Disarming Report 0123 6
EN=1/5/6/7
108 en | Programming
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH