
Contact ID Format
Contact ID Format can identify hundreds of zones by their unique codes. This format provides
a single-digit Event Qualifier and a three-digit Event Code that quickly identifies the reported
condition.
In general, Contact ID Format is very simple because most of the Event Codes and Point ID
Codes are predefined. The base station software usually can identify an alarmed zone by its
Point ID Code and usually pays little attention to the Event Code.
– Contact ID Message Format
ACCT MT Q EEE GG CCC S
ACCT = Subscriber ID
MT = Message type, H
Q = Event Qualifier
1= New event or Opening
3= New restore or Closing
6= Previously reported off-normal event
EEE = Event Code
GG = Group Number (always 0)
CCC = Zone/ Contact ID, 000 is for no zone/ID message
S = Checksum digit
Note: Any 0 values must be sent as an 0x0A.
Contact ID Report Data.
SIA Format
AMAX panel 4000 supports SIA Format. SIA allows transmitting System ID, event code, zone
ID, area ID, event time and also event text.
Conettix IP Format
AMAX panel 4000 supports Conettix IP. AMAX panel 4000 with DX4020G and B426 are able to
connect to Bosch Receivers 6600/6100 using Conettix IP Format.
Event Description
CID SIA ALL
Event
KP
Recall
Dialer
Event
EN
Event
SYSTEM RESET √ √
BURG ALARM 1130 BA √ √ √ √
BURG ALARM RESTORE 3130 BR √
BURG 24HOUR 1133 BA √ √ √ √
BURG 24HOUR RESTORE 3133 BH √
SENSOR FAULT 1380 BT √
SENSOR FAULT RESTORE 3380 BJ √
SENSOR BYPASS 1570 BB √ √
SENSOR BYPASS RESTORE 3570 BU √
SENSOR TAMPER 1144 TT √ √ √
SENSOR TAMPER RESTORE 3144 TJ √
34 en | Settings
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH
Komentarze do niniejszej Instrukcji