Event Description CID SIA ALL
Event
KP
Recall
Dialer
Event
EN
Event
RF RECEIVER JAM 1344 XQ √
RF RECEIVER JAM RESTORE 3344 XH √
RF RECEIVER CONFIGURATION CONFILICT √
RF RECEIVER CONFIGURATION CONFILICT
RESTORE
√
RF POINT MISSING 1381 UY √
RF POINT MISSING RESTORE 3381 UJ √
RF POINT BATTERY FAULT 1384 XT √
RF POINT BATTERY FAULT RESTORE 3384 XR √
RF POINT FAULT 1380 BT √
RF POINT FAULT RESTORE 3380 BJ √
RF REPEATER MISSING 1382 UY √
RF REPEATER MISSING RESTORE 3382 UJ √
RF REPEATER BATTERY FAULT 1384 XT √
RF REPEATER BATTERY FAULT RESTORE 3384 XR √
RF REPEATER TAMPER 1383 XS √
RF REPEATER TAMPER RESTORE 3383 XJ √
RF REPEATER AC FAULT 1334 YP √
RF REPEATER AC FAULT RESTORE 3334 YR √
RF KEYFOB BATTERY FAULT 1384 XT √
RF KEYFOB BATTERY FAULT RESTORE 3384 XR √
RF KEYFOB PANIC ALARM 1120 PA √
RF KEYFOB SILENT ALARM 1122 HA √
RF CHANGE KEYFOB √
FIRE UNVERIFIED 1378 FG √ √
Receiver Network Programming Options
When the control panel transmits a report via network, the following options should be
programmed other than the IP Address and port:
Anti Reply
Anti-replay prevents unauthorized messages from being sent to the Central Monitoring Station
and being recognized as originating from the control panel.
Contact your central monitoring station for the correct setting.
Acknowledge Wait Time
7.1.4
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 37
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112
Komentarze do niniejszej Instrukcji