DX3010 Output Expansion Module
Installation
The alarm control panel supports up to two DX3010 output expansion modules. The module is
connected to Bosch option bus1 or 2. Each module supports eight fully programmable relay
outputs. Like on-board output, DX3010 can be programmed as the output following the area
such as alarm event, arming / disarming status event and zone alarm event.
For more information about installation, see DX3010 Installation Guide.
Also refer to , page 28 for more details.
Wiring
When the module is placed in the enclosure of the alarm control panel, the power supply for
the control panel or external power supply can be used. For separate installation, the external
power supply must be used.
Power Supply Wire diameter of 0.8mm Wire diameter of 1.2mm
Alarm Control Panel 12.2m 24.4m
External Power Supply 305m 610m
Table 5.6: Lengths of cable for DX3010