2 - Interior Instant
The interior instant zone will perform as below:
1. Disarm:
– same as the Instant Zone disarm status
2. AWAY Arm:
– same as the Instant Zone AWAY Arm status
3. STAY Arm:
– This Zone will be Ignored and performed as disarm. Refer to Section Keypad
Indicators, page 20 to see how the zone is displayed during exit time.
– When Zone is triggered, not bypassed and system is forced to arm, a Zone fault
report is send.
– When System is disarmed and zone is not restored before, a Zone fault restore
report is sent
3 - Delay
The delay zone will perform as below:
1. DISARM: Same as Instant zone disarm status
2. AWAY Arm:
– Zone normal - no Alarm / no report
– Zone triggered - Entry time starts - no Alarm / no report
– Disarming during entry time - no Alarm / no report
– Zone triggered - during exit time - no Alarm / no report
– Zone triggered - during entry time - no Alarm / no report
– Zone triggered - entry time is expired - Alarm / report
– (report is delayed for 30sec, when system is disarmed before, no report)
3. STAY ARM: Same as AWAY ARM performance.
– First delay zone will start the entry time; all other delay zones will follow.
– When System is disarmed and zone is not restored before, a Zone restore report is
sent.
4 - Interior Delay
The Interior delay zone will perform as below:
1. Disarm: same as the Instant Zone disarm status
2. AWAY Arm: same as the Delay Zone AWAY Arm status
3. STAY Arm:
– This Zone will be Ignored and performed as disarm.
– Refer to Section Keypad Indicators, page 20 to see how the zone is displayed during
exit time.
5 - Follower
The follower zone will perform as below:
1. Disarm:
– same as the Instant Zone disarm status
2. AWAY Arm:
– Zone normal - no Alarm / no report
– Zone triggered - Alarm / report
– Zone triggered - during exit time - no Alarm / no report
– Zone triggered - during entry time - no Alarm / no report
– The remaining Delay Time is handed over from the Delay Zone to the Follower Zone.
– The follower zone will performance as the same as a delay zone.
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 49
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112