Select this option to enable the Answering Machine Bypass feature when the system is armed.
When the system is disarmed, the control panel does not answer any incoming calls. This
option is beneficial in high telephone traffic installations where the control panel could
answer an incoming call.
8 – Use Bell 103 for FSK Format (Disabled=CCITT V21)
If this option is selected, the control panel uses the BELL 103 transmission frequency at 300
baud. If this option is not selected, the control panel uses the CCITT V21 transmission
frequency at 300 baud.
Item Location Default
Communicator Options 1 177 9
Value Description
1 Reporting functions allowed
2 Remote arming by telephone allowed
4 Answering machine bypass only when arrived
8 Use bell 103 for FSK format (Disabled=CCITT V21)
Communicator Options 2
1 – Arm/Disarm Reports Only if Previous Alarm
When selected, an Disarm Report is transmitted to the base station receiver when the system
is disarmed after an alarm occurred. When the system is armed, an Arming Report is
transmitted. An Arm or Disarm Report does not report again until the system registers another
alarm.
For a partitioned control panel, an Arm/Disarm Report is sent only for the area in which the
alarm occurred.
Notice!
If the system is disarmed when an alarm occurs, only an Arm Report is sent the next time the
system is armed.
A User Code with a priority set to Always Send Arm/Disarm Reports overrides this feature
(Arm/Disarm Reports are always sent for that User Code).
2 – Arm/Disarm Reports for STAY Mode 1 and STAY Mode 2
Select this option if Arm/Disarm Reports are required when the system is armed in STAY Mode
1 or STAY Mode 2.
If this option is selected, a Partial Arm Report is sent when the system is armed in STAY Mode
1 or STAY Mode 2.
4 – Delay Siren until Transmission Complete
If this option is selected, horn speaker, bell, and strobe outputs are not activated until after
the control panel sends the message and the base station receiver sends a kiss-off back to the
control panel. If multiple messages are transmitted, the sirens are activated after the last kiss-
off is sent.
If a Codepad Panic, Codepad Fire, or Codepad Medical Alarm is activated, horn speaker, bell,
and strobe outputs operate immediately.
8 – Extend Time to Wait for Handshake from 30 to 60 Sec