Location Description Default Value Setting
428 to 431,
434
Test Report Time 0, 0, 0, 0, 0 Test Reports
435 Test Reporting Options 1 Receiver 1 only
Table 5.2: Command 965 Defaults
Command 966 - Enable/Disable the Automatic Stepping of Locations
This command allows the automatic stepping of locations when programming in Installer’s
Programming Mode.
Programming with the remote codepad provides no visual indication that Auto Step Mode is
enabled.
To enable the automatic stepping of locations:
1. Enter the Installer Code (default = 1234) and press [#] to enter Installer’s Programming
Mode. Two beeps sound and the STAY and AWAY indicators flash on the remote codepad
to indicate you entered Installer’s Programming Mode. The remote codepad displays the
data stored in Location 000.
2. Enter [9 6 6 #]. Two beeps sound.
To disable the automatic stepping of locations:
Enter [9 6 6 #]. Two beeps sound.
Example (Auto Step Enabled)
To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is enabled:
1. Press [0 #]. You are positioned at Location 000 (the Primary Telephone Number for
Receiver 1).
2. Program the number by pressing: [10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 10 * 5 * 5 * 0*]
Example (Auto Step Disabled)
To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is disabled:
Press [0 #].
You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).
To program the number, press:
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 10 *# 5 * # 5 * # 0 *]
Command 999 - Display the Software Version Number
When using the remote codepad, this command displays the version of the control panel.
To display the software version number:
1. Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s
Programming Mode. If you are using the remote codepad, the STAY and AWAY indicators
flash to indicate you entered Installer’s Programming Mode.
2. Enter [9 9 9 #]. Two beeps sound. If you are using the remote codepad, the codepad
lights a zone indicator corresponding to the software version. (Example: version 1.0.0, in
location from 999 to 997 shows as 100.)
3. Press [#] to exit from this command and return to the Installer’s Programming Mode.
4. Enter [9 6 0 #] to exit from Installer's Programming Mode. The system returns to the
disarmed state. If you are using the remote codepad, the STAY and AWAY indicators are
extinguished to indicate the system is disarmed.
5.1.8
5.1.9
Control Panel Configuration | en 45
Installation Guide 2014.07 | 00n | F01U298026