System Operations
This section explains the general operations of the system: arming and disarming the system
in the three modes, isolating zones, initiating codepad alarms, and determining a fault.
Operations described in this chapter are based on use with the IUI–SOL–ICON codepad. For
the IUI-SOL-TEXT codepad, follow the prompts on the codepad display.
Arming the system in AWAY Mode
Arming the system in AWAY Mode is normally performed when you leave the premises and
require that all zones are activated in a ready state to detect an intrusion.
There are two different methods to arm the system in AWAY Mode. You can always use
method one. You can use method two only if Option 2 is enabled in Location 497 (refer to
Consumer Options 2, page 109).
If you must isolate a zone (or zones) before arming the system in AWAY Mode, refer to
Isolating zones, page 56.
Notice!
Single button arming in AWAY mode reports as user code number 00.
To arm the system in AWAY Mode (method one):
1. Enter your code and press [AWAY].
2. Two beeps sound, the AWAY indicator lights, and Exit Time starts.
To arm the system in AWAY Mode (method two):
Notice!
Select Option 2 in Location 497 to enable single button arming in AWAY Mode (refer to
Consumer Options 2, page 109).
1. Press and hold [AWAY].
2. When two beeps sound, release the button.
The AWAY indicator lights and Exit Time starts. If a zone is not sealed at the end of Exit Time,
the zone is automatically isolated and its indicator is lit on the remote codepad. The zone
becomes an active part of the system again as soon as it is resealed. For example, if a window
is open when Exit Time expires, the window is not an active part of the system until it is
closed. Opening the window after Exit Time expires causes an alarm.
Forced Arming
Arming the system when a zone is not sealed is known as forced arming. Refer Zone Options 2,
page 94 to enable forced arming for each zone.
If the AWAY indicator does not light and a long beep sounds when you attempt to arm the
system in AWAY Mode, forced arming is not permitted. If this is the case, you seal all zones or
manually isolate them before you can arm the system.
Disarming the system from AWAY Mode
When you enter the premises after the system is armed in AWAY Mode, you must disarm the
system from AWAY Mode to disable detection devices that activate the sirens, strobe, and bell
outputs.
If there was an alarm prior to disarming the system from AWAY Mode, a zone indicator flashes,
indicating a previous alarm in that zone.
To disarm the system from AWAY Mode:
6
6.1
6.2