Notice!
Consequences
To arm the system in STAY Mode 2:
1. Press and hold [0].
2. When two beeps sound, release the button.
The STAY indicator is lit and the Exit Time starts.
The indicators for any zones that are programmed to be automatically isolated in STAY Mode 2
flash until the Exit Time expires. At the end of Exit Time, the zone indicators are extinguished
and the codepad sounds one short beep.
If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and is lit
constantly on the remote codepad. The zone becomes an active part of the system again as
soon as it is resealed. For example, if a window is open when Exit Time expires, the window
does not become an active part of the system until it is closed. Opening the window after Exit
Time expires causes an alarm.
Forced Arming
Arming the system when a zone is not sealed is known as forced arming. Refer to
Section14.3.7Zone Options2on page 63 to enable forced arming for each zone.
If the STAY indicator does not light and a long beep sounds when attempting to arm the
system, forced arming is not permitted. If this is the case, you must seal all zones or manually
isolate them before you can arm the system.
Disarming the system from STAY Mode 2
There are two methods to disarm the system from STAY Mode 2. You can always use the first
method. You can use method two only if Option 4 is enabled in Location 497 (refer to
Section18.6Consumer
Options2on page 83).
To disarm the system from STAY Mode 2 (method one):
1. Enter your code and press [STAY].
2. Two beeps sound and the STAY indicator is extinguished. The system is now disarmed.
To disarm the system from STAY Mode 2 (method two):
A flashing zone indicator represents a previous alarm in that zone. If this is the case, a valid
User Code is required to disarm the system using method one. To enable method two, Option
4 in Location 497 must
be enabled (refer to Section18.6ConsumerOptions2on
page 83).
1. Press and hold [0].
2. When two beeps sound, release the button.
The STAY indicator is extinguished and the system is disarmed.
Notice!
Single button disarming from STAY Mode 2 reports as User Code00.
6.6
Control Panel System Operations | en 55
Installation Guide 2014.07 | 00n | F01U298026
Przeglądanie stron 54