Handover can be sequential or non-sequential. The default settings is sequential handover.
You can disable sequential handover by disabling Option 8 in Location 494
Handover Zone is not restored when the system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
2 – Delay-1 Zone
A Delay-1 Zone (Contact ID Event Code 130) has a delay time determined by the value in
Locations 466 and 467 After Entry Time expires, the system activates an alarm.
If a Delay-1 Zone is not restored when the system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
3 – Delay-2 Zone
A Delay-2 Zone (Contact ID Event Code 130) has a delay time determined by the value in
Locations 468 and 469. After Entry Time expires, the system activates an alarm.
If a Delay-2 Zone is not restored when the system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
6 – 24-Hour Medical Zone
A 24-Hour Medical Zone (Contact ID Event Code100) is always ready to activate the
communication module, horn speaker, bell, and strobe, whether the system is armed or
disarmed. A Medical Report is transmitted to the base station receiver. A 24-Hour Medical
Zone does not send a Restore Report until the zone is restored.
7 – 24-Hour Panic Zone
A 24-Hour Panic Zone (Contact ID Event Code 120) is always ready to activate the
communication module, horn speaker, bell, and strobe, whether the system is armed or
disarmed. A Panic Report is transmitted to the base station receiver. A 24-Hour Panic Zone
does not send a Restore Report until the zone is restored.
8 – 24-Hour Holdup Zone
A 24-Hour Holdup Zone (Contact ID Event Code122) is always ready to activate the
communication module, horn speaker, bell, and strobe, whether the system is armed or
disarmed. If you want the holdup alarm to be silent, select Option 4 in the first Zone Options
location. A 24-Hour Holdup Zone does not send a Restore Report until the zone is restored.
9 – 24-Hour Tamper Zone
A 24-Hour Tamper Zone (Contact ID Event Code137) is always ready to activate the
communication module, horn speaker, bell, and strobe, whether the system is armed or
disarmed. A 24-Hour Tamper zone does not send a Restore Report until the zone is restored.
11 – Keyswitch Zone
Use a Keyswitch Zone to connect a keyswitch to operate the system. The zone number is
reported as a User Code when arming and disarming using this method of operation. (Contact
ID Event Code 409 for Keyswitch Away Arm, 442 for Keyswitch Stay 1 Arm).
12 – 24-Hour Burglary Zone
A 24-Hour Burglary Zone (Contact ID Event Code133) is always ready to activate the
communication module, horn speaker, bell, and strobe, whether the system is armed or
disarmed. A 24-Hour Burglary zone does not send a Restore Report until the zone is restored.
13 – 24-Hour Fire Zone
A 24-Hour Fire Zone (Contact ID Event Code 110) is always ready to activate the
communication module, horn speaker, bell, and strobe, whether the system is armed or
disarmed. A distinct fire sound is emitted through the horn speaker to indicate this type of
alarm. This fire sound is completely different from the burglary sound. A 24-Hour Fire zone
does not send a Restore Report until the zone is restored.