Alarm Restore Code
Location 392 is ignored when programming the Alarm Restore code and is global for all zones.
A zone Restore Report is sent only to the receiving party to which the zone is allocated (for
example, Receiver 1 or Receiver 2).
RF Receiver Trouble Report
RF Signal Jamming (Contact ID Event Code 344, Point ID Code 821)
RF Receiver Tamper Switch (Contact ID Event Code 341, Point ID Code 821)
RF Receiver Failure (Contact ID Event Code 333, Point ID Code 821)
RF Receiver Trouble Restore Report
An RF Receiver Trouble Restore Report is sent to the base station receiver when the RF
receiver no longer registers RF Signal Jamming, RF Receiver Tamper Switch, or RF Receiver
Failure.
RF Low Battery Report
An RF Low Battery Report (Contact ID Event Code384) is sent to the base station receiver
when the battery voltage on a wireless zone falls below its corresponding low battery
condition. An RF Low Battery Restore Report is sent on the first valid signal after the battery is
replaced.
Arm/Disarm Reports
A Disarm Report (Contact ID Event Code 401) is sent to the base station receiver when the
system is disarmed from AWAY Mode. An Arm Report (Contact ID Event Code 401) is sent at
the end of Exit Time when the system is armed in AWAY Mode.
If an expanded format is selected, this code is used as the Expansion Code and the user
number that armed or disarmed the system follows in the same transmission.
To enable Arm/Disarm Reports in STAY Mode:
Select Option 2 in Location 178. To enable Arm/Disarm Reports only after a previous alarm,
select Option 1 in Location 178.
Codepad Duress Report
A Duress Report (Contact ID Event Code 121) is sent to the base station receiver when 9 is
added to the end of any valid User Code used to disarm the system. This alarm is always
silent. A Duress Alarm can be activated during Exit Time. In other words, if the system is
armed and then disarmed by adding 9 to the end of the User Code before Exit Time expires, a
Codepad Duress Report is transmitted. Adding 9 to the end of a User Code when arming the
system does not cause a Duress Alarm.
If you want a 3 to activate a Codepad Duress Alarm instead of 9, select Option 2 in Location
498.
Notice!
Restore Reports are not sent for this event.
17.6
17.7
17.8
17.9
17.10
17.11
Control Panel Reports | en 143
Installation Guide 2014.07 | 00n | F01U298026