1. Access your router’s web interface and find the IP address of the B426, e.g.
“192.168.226.127”. You can input the B426 IP address https://192.168.226.127 in your
PC IE to check some B426 parameters, notice the protocol is “https” not “http”.
2. Open A-Link Plus. Enter “admin” (lower case) as operator, “ADMIN” (all capitals) as
password.
3. Click File > Communication Setting and select the Local IP Address of your computer.
Enter the local port number.
4. Add a new customer, then open the customer interface.
5. Enter the customer information, and the Control Panel IP Address you found in step 1,
e.g. “192.168.226.127”.
6. Enter 7700 in the Control Panel Port field.
7. Open the Control Panel Configuration menu. Select Solution 2000 or Solution 3000
according to your control panel type.
8. Open the Link menu. Select Network Connect (TCP/IP SSL) and click Connect. A-Link
tries to connect to the control panel using the B426. A-Link is connected to the control
panel when the Connect button changes to Disconnect.
Connect A-Link Plus to the control panel using the B426
1. Click Upload from Control Panel. A-Link reads the parameters from the control panel and
displays the parameter value differences between the A-Link database and the control
panel database in a dialog box. There should be different parameters for “Network
Module 1” and “Network Module 2”.
2. Click “Yes” to replace the parameter values in A-Link with the parameter values in the
control panel.
3. Open the Control Panel Configuration menu and access the Solution2000/3000
configuration interface. Select Network Module Programming. Change the parameters for
Module 1 and Module 2 as indicated in the following table:
Parameter
Module 1 Module 2
Basic Network Settings Enter the B426 IP address,
example:192.168.226.127
Mail Information Change the parameters for
the sending mailbox if you set
the Email receiver.
Change the parameters for
the sending mailbox if you set
the Email receiver.
Maintenance > Web Access
Enable
Enable Enable
Primary Network Information
> Primary Network Access
Point Name
Enter the point name for your
GPRS server
Return to the Link menu and reconnect the control panel. Click Download to Control Panel to
complete the process.
Check the parameters in the control panel to verify the parameter value changes were
successfully downloaded.
Configure the control panel with a codepad:
1. Enter the Installer passcode (the default is 1234) and press [#] to enter Installer’s
Programming Mode.
Control Panel
Accessories | en 37
Installation Guide 2014.07 | 00n | F01U298026