4-70 Master Communication MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Diagnostic and Status Messages
Information on General Drive Status
All important status bits of the status machine of the drive are mapped to
parameter P-0-0115, Device control: Status word. Reading and
interpreting parameter P-0-0115 provides information on the current
status of the drive.
See Parameter Description "P-0-0115, Device control: status
word"
Status of Digital Inputs/Outputs and Analog Inputs
All digital and analog input values can already be read via parameters
before assignment to the internal drive parameters. The following applies:
digital inputs/outputs of the control module are mapped to parameter
P-0-0303
analog inputs values are displayed in the following parameters:
P-0-0210, Analog input 1
P-0-0211, Analog input 2 (only for MPB02 firmware!)
P-0-0228, Analog input 3
P-0-0229, Analog input 4
See also in chapter "Extended Drive Functions":
section "Digital Inputs/Outputs: Diagnostic and Status Messages"
section "Digital Inputs: Diagnostic and Status Messages"
section "Encoder Emulation: Diagnostic and Status Messages"