10-4 Handling, Diagnostic and Service Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Loading parameter values is required in the following cases:
initial commissioning of the motor (loading basic parameter values and
motor-specific parameter values)
serial commissioning of machine axes at series machines (loading the
values saved after initial commissioning)
reestablishing a defined original status (repeated loading of the values
saved after initial commissioning)
replacing the controller for servicing (loading the current parameter
values saved before servicing)
Possibilities of loading parameter values to the controller:
motor encoder data memory loading the parameter values by
command or via the control panel during initial motor commissioning
MMC loading the parameter values by command
"DriveTop" commissioning tool loading the parameter values from
external data carrier
control master loading the parameter values from master-side data
carrier
By means of checksum comparison, the control master can determine
whether the values of the application-specific parameter values currently
active in the drive correspond to the values saved on the master side.
S-0-0017, IDN list of all operation data
S-0-0192, IDN-list of backup operation data
S-0-0262, C07_x Load defaults procedure command
S-0-0263, C2300 Load working memory procedure command
S-0-0264, C2200 Backup working memory procedure command
S-0-0269, Parameter buffer mode
S-0-0270, Selected IDN list of operation data to backup
S-0-0293, C2400 Selectively backup working memory procedure
command
S-0-0326, Parameter checksum
S-0-0327, IDN list of checksum parameter
P-0-0013, IDN list of modified parameters
P-0-4023, C0400 Communication phase 2 transition
P-0-4065, Non-volatile memory active
P-0-4090, Index for C07 Load defaults procedure
P-0-4091, C2500 Copy IDN from optional memory to internal
memory
P-0-4092, C2600 Copy IDN from internal memory to optional
memory
Loading Parameter Values
Checksum of Parameter Values
Pertinent Parameters