Bosch PIN8 N1 Instrukcja Naprawy Strona 168

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 728
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 167
5-44 Motor, Mechanical Axis System, Measuring Systems MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Forms for Required Manufacturer-Side Output Data
Form for Output Data of Asynchronous Motors
Manufacturer,
motor type:_____________________________________
Customer, installation,
axis designation:________________________________
Designation
Symbol/short form
Unit Value see ...
rated power
1)
P
N
kW p. 5-34
rated torque
1)
M
N
Nm
rated current
1)
I
N
A
eff
p. 5-34
power factor
1)
cos ϕ
-- p. 5-34
magnetizing current
2)
I
Mag
A
eff
p. 5-42
rated speed
1)
n
N
min
-1
p. 5-36
rated frequency
1)
f
N
Hz p. 5-36
rated voltage
1)
U
N
V
eff
p. 5-36
contin. current at standstill
2)
I
d
A
eff
rated force
2)
F
N
N
inertia/mass J/m _ pp. 5-39
frequency for I
d
2)
f
Id
Hz
maximum speed
1)
or n
max
min
-1
maximum velocity
2)
v
max
m/min
no. of pole pairs (rotary) or PPZ --
pole pair distance (linear) PWT (N-N-pol) mm
insulation class Isol.Kl. --
motor inductance, min. value L
U-V, min
mH p. 5-28
motor inductance, max. value L
U-V, max
mH p. 5-28
motor induct., average value L
U-V
mH p. 5-28
stator leakage inductance
*)
L mH p. 5-41
rotor leakage inductance
*)
L mH p. 5-41
motor magnetizing inductance
*)
L
H(Al-St)
mH p. 5-41
stator resistance (20°C)
*)
R
S(Al-St)
ohm p. 5-41
rotor resistance (20°C)
*)
R
R(Al-St)
ohm p. 5-41
rotor time constant
*)
T
R
ms p. 5-41
winding resistance (20°C) R
U-V
ohm p. 5-39
allowed periodic peak voltage û
max_zul.
V
pp/2
p. 5-28
allowed rate of rise of voltage du/dt
zul.
kV/µs p. 5-28
cooling type (without/with blower, liquid cooling) --
tpye of motor rotary/linear --
Does rotor/secondary part have closed slots? Y/N
Fig. 5-61: Motor data
(
1)
type plate data with rotary motor;
2)
only with linear motors;
*)
helpful, but not obligatory data)
Note: Also take form for output data of motor temperature sensor
and motor encoder into account (see below)!
________________________________________________________
Name Date Signature