8-92 Drive Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Pertinent Diagnostic Messages
A0011 Starting lockout active
E3110 Time interval for forced dynamization exceeded
F8027 Starting lockout while drive enabled
Integrated Safety Functions
The following configurable control sections can use the integrated safety
functions if they have been equipped with the optional safety module S1:
single-axis ADVANCED (CSH01.1C)
double-axis BASIC UNIVERSAL (CDB01.1C)
Features
Safety related stopping process:
"Safety related standstill" corresponding to stop category 1
according to EN 60204-1 (with drive-controlled best possible
deceleration and time monitoring)
or, alternatively,
"Safety related operational stop" corresponding to stop category 2
according to EN 60204-1, i.e. the drive control remains active.
Transition to standstill is carried out by the NC. Using 2 channels,
the drive monitors the attainment of standstill within the preset
tolerance time
additionally
"Safety related drive interlock" like "Safety related standstill", but
switching to "Safety related motion" by actuating the enabling
control device is not possible
Safety switches S1/S2 are used to select "Safety related
standstill"/"Safety related operational stop". Separate switches
ASP1/ASP2 are used to select the starting lockout.
Safety related motion:
Safety related reduced speed
2-channel monitoring for exceeding a velocity threshold
Safety related direction of motion
2-channel monitoring for allowed direction of motion
Safety related limited increment
2-channel monitoring for allowed travel distance
Safety related limited absolute position
2-channel monitoring for allowed absolute position. Safety
related homing must be executed for the safety related absolute
position!
Safety related acceleration/deceleration
2-channel monitoring for maximum deceleration/acceleration
Safety related feedback:
Safety related diagnosis outputs
to transfer the "Safety related status" to additional system
components
Safety related safety door
A drive that functions as the diagnostic master can summarize
the safety related status of several axes within a protective zone
and control a safety door.