MPH-02, MPB-02, MPD-02 Drive Control 6-45
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Before starting the command "automatic control loop setting", the default
controller parameters stored in the motor encoder data memory should be
loaded or the data of the motor data sheet should be entered in the
respective parameters.
An oscillation for automatic control loop setting is only carried out when
the following requirements have been fulfilled:
drive enable is present
drive start has been set
All parameters used for the command "automatic control loop setting"
must be determined before command start so that they take effect for the
automatic control loop setting.
P-0-0163, Damping factor for autom. controller adjust
to select the desired control loop dynamics
P-0-0164, Application for autom. controller adjust
to take the mechanical properties into account for controller
optimization
P-0-0165, Selection for autom. controller adjust
to select the functionality (modes) of the automatic control loop
setting
Chronological Sequence of Automatic Control Loop
Setting
The automatic control loop setting is carried out in the following steps:
8. start command and make check for possible command errors
9. determine total and extrinsic inertia by evaluating acceleration and
deceleration processes
10. calculate and activate controller parameters in drive taking P-0-0163,
Damping factor for autom. controller adjust and P-0-0164,
Application for autom. controller adjust into account
11. check velocity control loop and correct controller parameters, if need
be, until desired behavior occurs (depends on dynamics
programmed)
12. check position control loop and correct controller parameters, if need
be, until aperiodic behavior in position control loop occurs
13. wait for possible restart or end of command
During this step the drive is idle (velocity = 0) and the display reads
"C1800".
Loading the Default Controller
Parameters
Drive Enable and Drive Start
Parameter Settings
Steps of Automatic Control Loop
Setting